A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers.
Metrics
Affected Vendors & Products
References
History
Sat, 16 Aug 2025 21:45:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Rockwellautomation
Rockwellautomation factorytalk Linx |
|
| Vendors & Products |
Rockwellautomation
Rockwellautomation factorytalk Linx |
Thu, 14 Aug 2025 16:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
Thu, 14 Aug 2025 15:00:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers. | |
| Title | Rockwell Automation FactoryTalk® Linx Network Browser Security Bypass Vulnerability | |
| Weaknesses | CWE-286 | |
| References |
| |
| Metrics |
cvssV4_0
|
Status: PUBLISHED
Assigner: Rockwell
Published:
Updated: 2025-08-14T15:08:22.952Z
Reserved: 2025-07-21T19:25:20.271Z
Link: CVE-2025-7972
Updated: 2025-08-14T15:06:48.813Z
Status : Awaiting Analysis
Published: 2025-08-14T15:15:42.413
Modified: 2025-08-15T13:12:51.217
Link: CVE-2025-7972
No data.