A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected product does not properly validate a length field in a serialized message which it uses to determine the amount of memory to be allocated for deserialization. This could allow an unauthenticated remote attacker to cause the application to allocate exhaustive amounts of memory and subsequently create a partial denial of service condition. Successful exploitation is only possible in redundant Telecontrol Server Basic setups and only if the connection between the redundant servers has been disrupted.
History

Tue, 19 Aug 2025 15:00:00 +0000

Type Values Removed Values Added
CPEs cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*

Thu, 17 Apr 2025 11:15:00 +0000

Type Values Removed Values Added
Description A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected product does not properly validate a length field in a serialized message which it uses to determine the amount of memory to be allocated for deserialization. This could allow an unauthenticated remote attacker to cause the application to allocate exhaustive amounts of memory and subsequently create a partial denial of service condition. Successful exploitation is only possible in redundant Telecontrol Server Basic setups and only if the connection between the redundant servers has been disrupted.
Weaknesses CWE-130
References
Metrics cvssV3_1

{'score': 3.7, 'vector': 'CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L'}

cvssV4_0

{'score': 6.3, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N'}


cve-icon MITRE

Status: PUBLISHED

Assigner: siemens

Published:

Updated: 2025-04-17T14:43:50.005Z

Reserved: 2025-03-12T13:47:09.580Z

Link: CVE-2025-29931

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Analyzed

Published: 2025-04-17T11:15:47.807

Modified: 2025-08-19T14:48:34.130

Link: CVE-2025-29931

cve-icon Redhat

No data.