Filtered by vendor Tenda Subscriptions
Filtered by product O3v2 Subscriptions
Total 12 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2025-7421 1 Tenda 3 O3, O3 Firmware, O3v2 2025-07-16 8.8 High
A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been rated as critical. This issue affects the function fromMacFilterModify of the file /goform/operateMacFilter of the component httpd. The manipulation of the argument mac leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7422 1 Tenda 3 O3, O3 Firmware, O3v2 2025-07-16 8.8 High
A vulnerability classified as critical has been found in Tenda O3V2 1.0.0.12(3880). Affected is the function setAutoReboot of the file /goform/setNetworkService of the component httpd. The manipulation of the argument week leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7423 1 Tenda 3 O3, O3 Firmware, O3v2 2025-07-16 8.8 High
A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). Affected by this vulnerability is the function formWifiMacFilterSet of the file /goform/setWrlFilterList of the component httpd. The manipulation of the argument macList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7417 1 Tenda 3 O3, O3 Firmware, O3v2 2025-07-16 8.8 High
A vulnerability has been found in Tenda O3V2 1.0.0.12(3880) and classified as critical. Affected by this vulnerability is the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument ip leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7418 1 Tenda 3 O3, O3 Firmware, O3v2 2025-07-16 8.8 High
A vulnerability was found in Tenda O3V2 1.0.0.12(3880) and classified as critical. Affected by this issue is the function fromPingResultGet of the file /goform/setPing of the component httpd. The manipulation of the argument destIP leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7419 1 Tenda 3 O3, O3 Firmware, O3v2 2025-07-16 8.8 High
A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been classified as critical. This affects the function fromSpeedTestSet of the file /goform/setRateTest of the component httpd. The manipulation of the argument destIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7420 1 Tenda 3 O3, O3 Firmware, O3v2 2025-07-16 8.8 High
A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been declared as critical. This vulnerability affects the function formWifiBasicSet of the file /goform/setWrlBasicInfo of the component httpd. The manipulation of the argument extChannel leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7414 1 Tenda 3 O3, O3 Firmware, O3v2 2025-07-16 6.3 Medium
A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7415 1 Tenda 3 O3, O3 Firmware, O3v2 2025-07-16 6.3 Medium
A vulnerability, which was classified as critical, has been found in Tenda O3V2 1.0.0.12(3880). This issue affects the function fromTraceroutGet of the file /goform/getTraceroute of the component httpd. The manipulation of the argument dest leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7416 1 Tenda 3 O3, O3 Firmware, O3v2 2025-07-16 8.8 High
A vulnerability, which was classified as critical, was found in Tenda O3V2 1.0.0.12(3880). Affected is the function fromSysToolTime of the file /goform/setSysTimeInfo of the component httpd. The manipulation of the argument Time leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-34338 1 Tenda 3 O3, O3 Firmware, O3v2 2025-06-30 7.2 High
Tenda O3V2 with firmware versions V1.0.0.10 and V1.0.0.12 was discovered to contain a Blind Command Injection via dest parameter in /goform/getTraceroute. This vulnerability allows attackers to execute arbitrary commands with root privileges. Authentication is required to exploit this vulnerability.
CVE-2024-6962 1 Tenda 3 O3, O3 Firmware1.0.0.10\(2478\), O3v2 2024-11-21 8.8 High
A vulnerability classified as critical was found in Tenda O3 1.0.0.10. This vulnerability affects the function formQosSet. The manipulation of the argument remark/ipRange/upSpeed/downSpeed/enable leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272116. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.