Filtered by vendor Schneider-electric
Subscriptions
Total
781 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2013-0687 | 1 Schneider-electric | 1 Micom S1 Studio | 2025-04-11 | N/A |
The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file. | ||||
CVE-2013-0664 | 1 Schneider-electric | 3 Modicon M340, Modicon Premium, Modicon Quantum Plc | 2025-04-11 | N/A |
The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests. | ||||
CVE-2012-1990 | 1 Schneider-electric | 2 Kerweb, Kerwin | 2025-04-11 | N/A |
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric Kerweb before 3.0.1 and Kerwin before 6.0.1 allow remote attackers to inject arbitrary web script or HTML via (1) the evtvariablename parameter in an evts.xml action to kw.dll, (2) unspecified search fields, or (3) unspecified content-display fields. | ||||
CVE-2013-0658 | 1 Schneider-electric | 1 Accutech Manager | 2025-04-11 | N/A |
Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request. | ||||
CVE-2013-0655 | 1 Schneider-electric | 1 Software Update Utility | 2025-04-11 | N/A |
The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in-the-middle attackers to spoof updates, and consequently execute arbitrary code, by modifying the data stream on TCP port 80. | ||||
CVE-2013-2761 | 1 Schneider-electric | 1 Modicon M340 | 2025-04-11 | N/A |
The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service (module crash) via crafted FTP traffic, as demonstrated by the FileZilla FTP client. | ||||
CVE-2013-0657 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-04-11 | N/A |
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol. | ||||
CVE-2013-2796 | 1 Schneider-electric | 3 Citectscada, Powerlogic Scada, Vijeo Citect | 2025-04-11 | N/A |
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. | ||||
CVE-2013-0663 | 1 Schneider-electric | 3 Modicon M340, Modicon Premium, Modicon Quantum Plc | 2025-04-11 | N/A |
Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials. | ||||
CVE-2011-3330 | 1 Schneider-electric | 6 Monitor Pro, Opc Factory Server, Pl7 Pro and 3 more | 2025-04-11 | N/A |
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter. | ||||
CVE-2023-3001 | 1 Schneider-electric | 1 Igss Dashboard | 2025-03-05 | 7.8 High |
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. | ||||
CVE-2022-34755 | 1 Schneider-electric | 1 Easergy Builder Installer | 2025-03-03 | 6.3 Medium |
A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation process initiated by a valid user. Affected Products: Easergy Builder Installer (1.7.23 and prior) | ||||
CVE-2023-25548 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-03-03 | 8.8 High |
A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
CVE-2023-25552 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-03-03 | 8.1 High |
A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthorized functions when tampering the Device File Transfer settings on DCE endpoints. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
CVE-2023-25549 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-03-03 | 7.2 High |
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
CVE-2023-4516 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-27 | 7.8 High |
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow a local attacker to change update source, potentially leading to remote code execution when the attacker force an update containing malicious content. | ||||
CVE-2023-5402 | 1 Schneider-electric | 1 C-bus Toolkit | 2025-02-27 | 9.8 Critical |
A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote code execution when the transfer command is used over the network. | ||||
CVE-2023-5399 | 1 Schneider-electric | 1 Spacelogic C-bus Toolkit | 2025-02-27 | 9.8 Critical |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the File Command. | ||||
CVE-2023-5391 | 1 Schneider-electric | 3 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports, Ecostruxure Power Scada Operation With Advanced Reports | 2025-02-27 | 9.8 Critical |
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application. | ||||
CVE-2023-25551 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-12 | 6.1 Medium |
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) |