| CVE-2019-9009 | 1 Codesys | 14 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 11 more | 2024-11-21 | 7.5 High |
| An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash. | ||||
| CVE-2019-9008 | 1 Codesys | 10 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 7 more | 2024-11-21 | 8.8 High |
| An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime. | ||||
| CVE-2019-5105 | 1 Codesys | 1 Codesys | 2024-11-21 | 7.5 High |
| An exploitable memory corruption vulnerability exists in the Name Service Client functionality of 3S-Smart Software Solutions CODESYS GatewayService. A specially crafted packet can cause a large memcpy, resulting in an access violation and termination of the process. An attacker can send a packet to a device running the GatewayService.exe to trigger this vulnerability. All variants of the CODESYS V3 products in all versions prior V3.5.16.10 containing the CmpRouter or CmpRouterEmbedded component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PLCnext, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit, CODESYS V3 Embedded Target Visu Toolkit, CODESYS V3 Remote Target Visu Toolkit, CODESYS V3 Safety SIL2, CODESYS Edge Gateway V3, CODESYS Gateway V3, CODESYS HMI V3, CODESYS OPC Server V3, CODESYS PLCHandler SDK, CODESYS V3 Simulation Runtime (part of the CODESYS Development System). | ||||
| CVE-2019-19789 | 1 Codesys | 3 Plcwinnt, Runtime Toolkit, Sp Realtime Nt | 2024-11-21 | 6.5 Medium |
| 3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4.7.54, and CODESYS PLCWinNT before V2.4.7.54 allow a NULL pointer dereference. | ||||
| CVE-2019-18858 | 1 Codesys | 14 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 11 more | 2024-11-21 | 9.8 Critical |
| CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. | ||||
| CVE-2019-16265 | 1 Codesys | 2 Codesys, Eni Server | 2024-11-21 | 9.8 Critical |
| CODESYS V2.3 ENI server up to V3.2.2.24 has a Buffer Overflow. | ||||
| CVE-2019-13548 | 1 Codesys | 13 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 10 more | 2024-11-21 | 9.8 Critical |
| CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. | ||||
| CVE-2019-13542 | 1 Codesys | 10 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 7 more | 2024-11-21 | 6.5 Medium |
| 3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition. | ||||
| CVE-2019-13538 | 1 Codesys | 1 Codesys | 2024-11-21 | 8.6 High |
| 3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only. | ||||
| CVE-2019-13532 | 1 Codesys | 13 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 10 more | 2024-11-21 | 7.5 High |
| CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller. | ||||
| CVE-2018-20026 | 1 Codesys | 18 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 15 more | 2024-11-21 | 7.5 High |
| Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0. | ||||
| CVE-2018-20025 | 1 Codesys | 15 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 12 more | 2024-11-21 | N/A |
| Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0. | ||||
| CVE-2018-10612 | 1 Codesys | 12 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 9 more | 2024-11-21 | N/A |
| In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials. | ||||
| CVE-2024-6876 | 1 Codesys | 1 Oscat Basic Library | 2024-10-01 | 4.4 Medium |
| Out-of-Bounds read vulnerability in OSCAT Basic Library allows an local, unprivileged attacker to access limited internal data of the PLC which may lead to a crash of the affected service. | ||||
| CVE-2024-8175 | 1 Codesys | 18 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 15 more | 2024-09-26 | 7.5 High |
| An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS. | ||||