Filtered by vendor Siemens
Subscriptions
Total
2090 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2013-2780 | 1 Siemens | 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more | 2025-04-11 | N/A |
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port). | ||||
CVE-2012-3017 | 1 Siemens | 4 Simatic S7-400 Cpu 414-3 Pn\/dp, Simatic S7-400 Cpu 416-3 Pn\/dp, Simatic S7-400 Cpu 416f-3 Pn\/dp and 1 more | 2025-04-11 | N/A |
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets. | ||||
CVE-2013-4911 | 1 Siemens | 1 Wincc | 2025-04-11 | N/A |
Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SIMATIC HMI panels by the WinCC product. | ||||
CVE-2012-3009 | 1 Siemens | 1 Comos | 2025-04-11 | N/A |
Siemens COMOS before 9.1 Patch 413, 9.2 before Update 03 Patch 023, and 10.0 before Patch 005 allows remote authenticated users to obtain database administrative access via unspecified method calls. | ||||
CVE-2012-3015 | 1 Siemens | 2 Simatic Pcs7, Simatic Step 7 | 2025-04-11 | N/A |
Untrusted search path vulnerability in Siemens SIMATIC STEP7 before 5.5 SP1, as used in SIMATIC PCS7 7.1 SP3 and earlier and other products, allows local users to gain privileges via a Trojan horse DLL in a STEP7 project folder. | ||||
CVE-2013-0674 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | N/A |
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter. | ||||
CVE-2012-2597 | 1 Siemens | 1 Wincc | 2025-04-11 | N/A |
Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL. | ||||
CVE-2012-2596 | 1 Siemens | 1 Wincc | 2025-04-11 | N/A |
The XPath functionality in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 does not properly handle special characters in parameters, which allows remote authenticated users to read or modify settings via a crafted URL, related to an "XML injection" attack. | ||||
CVE-2013-4779 | 1 Siemens | 2 Enterprise Openscape Branch, Openscape Session Border Controller | 2025-04-11 | N/A |
Cross-site scripting (XSS) vulnerability in core/handleTw.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | ||||
CVE-2011-3321 | 1 Siemens | 2 Simatic Wincc Flexible Runtime, Simatic Wincc Runtime | 2025-04-11 | N/A |
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308. | ||||
CVE-2012-2595 | 1 Siemens | 1 Wincc | 2025-04-11 | N/A |
Multiple cross-site scripting (XSS) vulnerabilities in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 allow remote attackers to inject arbitrary web script or HTML via vectors involving special characters in parameters. | ||||
CVE-2013-0668 | 1 Siemens | 1 Wincc Tia Portal | 2025-04-11 | N/A |
Multiple cross-site scripting (XSS) vulnerabilities in the HMI web application in Siemens WinCC (TIA Portal) 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL. | ||||
CVE-2012-2598 | 1 Siemens | 1 Wincc | 2025-04-11 | N/A |
Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input. | ||||
CVE-2013-4651 | 1 Siemens | 17 Scalance W700 Series Firmware, Scalance W744-1, Scalance W744-1pro and 14 more | 2025-04-11 | N/A |
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship. | ||||
CVE-2010-2772 | 1 Siemens | 2 Simatic Pcs 7, Simatic Wincc | 2025-04-11 | 7.8 High |
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568. | ||||
CVE-2012-1803 | 1 Siemens | 1 Ruggedcom Rugged Operating System | 2025-04-11 | N/A |
RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session. | ||||
CVE-2011-4879 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | N/A |
miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request. | ||||
CVE-2013-3959 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | N/A |
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. | ||||
CVE-2011-4878 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | N/A |
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI. | ||||
CVE-2011-4877 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | N/A |
HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP. |