Filtered by vendor Schneider-electric
Subscriptions
Total
768 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-5559 | 1 Schneider-electric | 2 Powerlogic P5, Powerlogic P5 Firmware | 2024-11-21 | 6.1 Medium |
CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could cause denial of service, device reboot, or an attacker gaining full control of the relay when a specially crafted reset token is entered into the front panel of the device. | ||||
CVE-2024-5558 | 1 Schneider-electric | 4 Spacelogic As-b, Spacelogic As-b Firmware, Spacelogic As-p and 1 more | 2024-11-21 | 6.4 Medium |
CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could cause escalation of privileges when an attacker abuses a limited admin account. | ||||
CVE-2024-5557 | 1 Schneider-electric | 4 Spacelogic As-b, Spacelogic As-b Firmware, Spacelogic As-p and 1 more | 2024-11-21 | 4.5 Medium |
CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause exposure of SNMP credentials when an attacker has access to the controller logs. | ||||
CVE-2024-5313 | 1 Schneider-electric | 2 Evlink Home, Evlink Home Firmware | 2024-11-21 | 6.5 Medium |
CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH interface over the product network interface. This does not allow to directly exploit the product or make any unintended operation as the SSH interface access is protected by an authentication mechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts to perform a potential denial of service attack on the exposed SSH interface. | ||||
CVE-2024-5056 | 1 Schneider-electric | 6 Bmxnoe0100, Bmxnoe0100 Firmware, Bmxnoe0110 and 3 more | 2024-11-21 | 6.5 Medium |
CWE-552: Files or Directories Accessible to External Parties vulnerability exists which may prevent user to update the device firmware and prevent proper behavior of the webserver when specific files or directories are removed from the filesystem. | ||||
CVE-2024-37040 | 1 Schneider-electric | 7 Sage 1410, Sage 1430, Sage 1450 and 4 more | 2024-11-21 | 5.4 Medium |
CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request. | ||||
CVE-2024-37039 | 1 Schneider-electric | 7 Sage 1410, Sage 1430, Sage 1450 and 4 more | 2024-11-21 | 5.9 Medium |
CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request. | ||||
CVE-2024-37038 | 1 Schneider-electric | 7 Sage 1410, Sage 1430, Sage 1450 and 4 more | 2024-11-21 | 7.5 High |
CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests. | ||||
CVE-2024-37037 | 1 Schneider-electric | 7 Sage 1410, Sage 1430, Sage 1450 and 4 more | 2024-11-21 | 8.1 High |
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request. | ||||
CVE-2024-37036 | 1 Schneider-electric | 7 Sage 1410, Sage 1430, Sage 1450 and 4 more | 2024-11-21 | 9.8 Critical |
CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set. | ||||
CVE-2024-2747 | 1 Schneider-electric | 1 Easergy Studio | 2024-11-21 | 7.8 High |
CWE-428: Unquoted search path or element vulnerability exists in Easergy Studio, which could cause privilege escalation when a valid user replaces a trusted file name on the system and reboots the machine. | ||||
CVE-2024-2602 | 1 Schneider-electric | 1 Foxrtu Station | 2024-11-21 | 7.3 High |
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could result in remote code execution when an authenticated user executes a saved project file that has been tampered by a malicious actor. | ||||
CVE-2024-0865 | 1 Schneider-electric | 1 Ecostruxure It Gateway | 2024-11-21 | 7.8 High |
CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege escalation when logged in as a non-administrative user. | ||||
CVE-2023-7032 | 1 Schneider-electric | 1 Easergy Studio | 2024-11-21 | 7.8 High |
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker logged in with a user level account to gain higher privileges by providing a harmful serialized object. | ||||
CVE-2023-6407 | 2 Microsoft, Schneider-electric | 6 Windows 10 1507, Windows 11 21h2, Windows Server 2016 and 3 more | 2024-11-21 | 5.3 Medium |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker. | ||||
CVE-2023-6032 | 1 Schneider-electric | 4 Galaxy Vl, Galaxy Vl Firmware, Galaxy Vs and 1 more | 2024-11-21 | 5.3 Medium |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause a file system enumeration and file download when an attacker navigates to the Network Management Card via HTTPS. | ||||
CVE-2023-5987 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2024-11-21 | 6.1 Medium |
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload. | ||||
CVE-2023-5985 | 1 Schneider-electric | 4 Ion8650, Ion8650 Firmware, Ion8800 and 1 more | 2024-11-21 | 4.8 Medium |
A CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability exists that could cause compromise of a user’s browser when an attacker with admin privileges has modified system values. | ||||
CVE-2023-5984 | 1 Schneider-electric | 4 Ion8650, Ion8650 Firmware, Ion8800 and 1 more | 2024-11-21 | 7.2 High |
A CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user begins a firmware update procedure which could result in full control over the device. | ||||
CVE-2023-5630 | 1 Schneider-electric | 32 Eb450, Eb450 Firmware, Eb45e and 29 more | 2024-11-21 | 6.5 Medium |
A CWE-494: Download of Code Without Integrity Check vulnerability exists that could allow a privileged user to install an untrusted firmware. |