Filtered by vendor Advantech Subscriptions
Total 382 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2024-50366 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50367 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "sta_log_htm" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50368 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50369 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50370 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.
CVE-2024-50371 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation.
CVE-2024-50372 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.
CVE-2024-50373 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.
CVE-2024-50374 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.
CVE-2024-50375 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 9.8 Critical
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
CVE-2024-50376 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 7.3 High
A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.
CVE-2024-50377 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-01-23 6.5 Medium
A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password.
CVE-2025-52694 1 Advantech 7 Iot Edge Linux Docker, Iot Edge Products, Iot Edge Windows and 4 more 2026-01-22 10 Critical
Successful exploitation of the SQL injection vulnerability could allow an unauthenticated remote attacker to execute arbitrary SQL commands on the vulnerable service when it is exposed to the Internet.
CVE-2025-63701 1 Advantech 3 Tp-3250, Tp 3250, Tp 3250 Firmware 2026-01-12 6.8 Medium
A heap corruption vulnerability exists in the Advantech TP-3250 printer driver's DrvUI_x64_ADVANTECH.dll (v0.3.9200.20789) when DocumentPropertiesW() is called with a valid dmDriverExtra value but an undersized output buffer. The driver incorrectly assumes the output buffer size matches the input buffer size, leading to invalid memory operations and heap corruption. This vulnerability can cause denial of service through application crashes and potentially lead to code execution in user space. Local access is required to exploit this vulnerability.
CVE-2025-14252 1 Advantech 1 Susi 2026-01-07 7.8 High
An Improper Access Control vulnerability in Advantech SUSI driver (susi.sys) allows attackers to read/write arbitrary memory, I/O ports, and MSRs, resulting in privilege escalation, arbitrary code execution, and information disclosure. This issue affects Advantech SUSI: 5.0.24335 and prior.
CVE-2025-14848 1 Advantech 2 Webaccess/scada, Webaccess\/scada 2025-12-31 4.3 Medium
Advantech WebAccess/SCADA is vulnerable to absolute directory traversal, which may allow an attacker to determine the existence of arbitrary files.
CVE-2025-14849 1 Advantech 2 Webaccess/scada, Webaccess\/scada 2025-12-31 8.8 High
Advantech WebAccess/SCADA  is vulnerable to unrestricted file upload, which may allow an attacker to remotely execute arbitrary code.
CVE-2025-14850 1 Advantech 2 Webaccess/scada, Webaccess\/scada 2025-12-31 8.1 High
Advantech WebAccess/SCADA is vulnerable to directory traversal, which may allow an attacker to delete arbitrary files.
CVE-2025-46268 1 Advantech 2 Webaccess/scada, Webaccess\/scada 2025-12-31 6.3 Medium
Advantech WebAccess/SCADA  is vulnerable to SQL injection, which may allow an attacker to execute arbitrary SQL commands.
CVE-2025-67653 1 Advantech 2 Webaccess/scada, Webaccess\/scada 2025-12-31 4.3 Medium
Advantech WebAccess/SCADA is vulnerable to directory traversal, which may allow an attacker to determine the existence of arbitrary files.